Servicing and replacement
The 12 V battery is maintenance-free.
Contact an authorized Volvo workshop if the 12 V battery needs to be replaced.
Important
12 V terminal
In the event of a total loss of power, the vehicle can't be unlocked, as the locks are electrically operated. To access the vehicle and charge it, the vehicle can be powered for a short time using the externally accessible 12 V terminal. It can be accessed by removing a small panel below the front bumper, near the front left wheel.
Before any use of the 12 V terminal, consider the following:
- Volvo recommends that the 12 V terminal only be used by service technicians for the purpose of accessing the vehicle as part of immobilization recovery.
- Only use a 12 V charger with a maximum charging current of less than 40 A.
- Connecting any power source that delivers current higher than 40 A will blow the terminal's fuse, thereby disabling it.
- Only use the 12 V terminal for short amounts of time. This is not meant as a way of powering the vehicle continuously.
Battery type | AGM H4 |
Voltage | 12 V |
Dimensions (length × width × height) | 207 × 175 × 190 mm (85⁄₃₂ × 657⁄64 × 7³¹⁄64 in) |
Capacity | 50 Ah |
Cold start capacity1 | 540 A |